-TITANIUM sheath 5500 watt element, rated 240 volts 5.5kw or 120v 1.375kW -Underwriters Laboratories Recognized Component-Installation guide -2 Ridged molded gaskets for your heater flanges.-Fits industry standard flo-thru heaters with 2.25" outside diameter stainless steel housing. Does not fit 2.0" diameter housings, nor 1.9". -On 120v this element is 1375 watts.-Terminal bulkhead fittings are industry standard 1/2" diameter spaced 1-1/4" apart.-Titanium is the most corrosion resistant sheath material presently available, more resistant than Incoloy elements. NOTE: the color of the finished titanium after heat treating can be a dull grey color, to purple, to bluish-purple, and they do vary, and we do not havecolor choices nor any control over this, and functionally they are exactly the same. The grey-blue-purple color is the natural color for this titanium alloy.
Spa Heater Element Side Terminals Style, Flo-Thru Hot Tub Heating Coil 5.5kw 230/115v, new side terminal Flo-Thru heater element, Titanium sheath. Rated 240 volts 5.5kw AND 120 volts 1.375kw Heater housing gaskets (2) included. Compatible with Balboa M-7 type heaters, where the overall length must be 9.9" or less and must have the correct terminal placement. Certified, guaranteed good resistance and thoroughly ground fault tested, prior to shipping. Over 31 electrical tests performed.
Includes 2 new heater housing gaskets, standard size for flanged flo-thru heaters, Startup procedure is VERY important, just because it is titanium does not make it any more resistant to dry-fire abuse, starting up with air in the piping, etc., please read the included instructions. Can be run on 230v as 5.5kw (5500 watts) or on 115v 1.375kw (1375 watts), fits many flo-thru heaters requiring side terminals, Balboa M-7, Gecko, Acura controls as well as Morgan, Brett, United, ACC, Hydroquip, and many others. Includes an installation guide with tips on proper heating element startup (VERY important!). Sized for 2.25" diameter flo-thru heater housings with 1-1/4" terminal spacing, with 1/2" bulkhead holes in housing, these are all very common, standard dimensions. Overall length of this element is approximately 9-3/4".
From Spa Pumps And More. Not for housings smaller than 2.25" outside diameter, not for terminal spacing other than 1-1/4", not for hole size other than 1/2" terminal holes in housing, and not for replacing elements with centered terminals, please note. If you have a need for some other style or size, message us with those details please. For a proper fit you need your heater housing to conform to the details listed which again are: Stainless Steel Housing outside diameter must be 2.25" (2-1/4 inch) Housing hole size for terminals must be 1/2 inch. Housing hole spacing must be 1-1/4 inch center to center.
Housing must require an element with terminals offset to one side. Housing must require an overall element length of approximately 9-3/4 inch. Only UNOPENED new elements may be returned. FREE Shipping via 1st class mail and tracking will be uploaded to classifieds board for you. Thanks for looking!